| SOMMER CABLE - SC-SCUBA 14 HIGHFLEX |
| Construction | (2LI2Y0,14mm2)CY |
| Jacket, diameter | PVC 3,8 mm |
| AWG | 26 |
| No. of inner conductors | 2 x 0,14 mm2 |
| Copper strand per conductor | 18 x 0,10 mm |
| Conductor insulation | PE 1,15 mm |
| Shielding | copper braiding with 0.10 mm indiv. strand tin-plated |
| Shielding factor | 90 % |
| Temperature range | min. -25 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,09 kWh |
| Weight per 1 m | 25 g |
| Packaging | 100/500 m roll |
| Capac. cond./cond. per 1 m | 65 pF |
| Capac. cond./shield. per 1 m | 130 pF |
| Cond. resistance per 1 km | < 135 Ohm |
| Shield. resistance per 1 km | < 30 Ohm |
| Insulation resist. per 1 km | > 1 GOhm |
| Surge impedance | approx. 100 Ohm |
| black | red | green | grey | yellow | |
| SOMMER CABLE - SC-GOBLIN |
| Construction | (2LI2Y0.14mm2)(ST)DY |
| Jacket, diameter | PVC 4,6 mm |
| AWG | 26 |
| No. of inner conductors | 2 x 0,14 mm2 |
| Copper strand per conductor | 18 x 0,10 mm |
| Conductor insulation | PE 1,05 mm |
| Shielding | copper spiral sleeve tin-plated + metalic fleece |
| Shielding factor | 100 % |
| Temperature range | min. -25 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,10 kWh |
| Weight per 1 m | 27 g |
| Packaging | 100 m roll |
| Capac. cond./cond. per 1 m | 65 pF |
| Capac. cond./shield. per 1 m | 120 pF |
| Cond. resistance per 1 km | < 140 Ohm |
| Shield. resistance per 1 km | 30 Ohm |
| Insulat. resistance per 1 km | > 200 MOhm |
| white | black | blue | red | icy gray | |
| SOMMER CABLE - SC-PEACOCK MKII |
| Construction | {2(2LI2Y0,22mm2)DY}Y |
| Jacket, outer dimension | PVC 4,5 x 9,2 mm |
| AWG | 24 |
| No. of inner conductors | 2 x 2 x 0,22 mm2 |
| Copper strand per conductor | 28 x 0,10 mm |
| Conductor insulation | Foam/skin-PE 1,3 mm |
| Shielding | copper spiral shielding |
| Shielding factor | 95 % |
| Temperature range | min. -30 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,18 kWh |
| Weight per 1 m | 49 g |
| Packaging | 100 m roll |
| Capac. cond./cond. per 1 m | 70 pF |
| Capac. cond./shield. per 1 m | 125 pF |
| Cond. resistance per 1 km | < 90 Ohm |
| Shield. resistance per 1 km | 36 Ohm |
| Insulat. resistance per 1 km | > 500 MOhm |
| Surge impedance per 1 km | 110 Ohm |
| black | |
| SOMMER CABLE - SC-CICADA SO-D14 |
| Construction | (2LI2Y0.14mm2)DY |
| Jacket, diameter | PUR Master Blend 2,6 mm |
| AWG | 26 |
| No. of inner conductors | 2 x 0,14 mm2 |
| Copper strand per conductor | 18 x 0,10 mm |
| Cond. insulation | PE 0,90 mm |
| Shielding | copper spiral shielding + filler strand, tin-plated (0.22 mm2) |
| Shielding factor | 95 % |
| Temperature range | min. -30 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,08 kWh |
| Weight per 1 m | 13 g |
| Packaging | 100 m roll |
| Capac. cond./cond. per 1 m | 65 pF |
| Capac. cond./shield. per 1 m | 120 pF |
| Cond. resistance per 1 km | < 148 Ohm |
| Shield. resistance per 1 km | 30 Ohm |
| Insulation resist. per 1 km | > 1 GOhm |
| black | |