Bulk Cables - Audio  |  Multipair Modulation Cable, Fixed installation, FRNC, Audio [AES/EBU]


SOMMER CABLE - SC-LOGICABLE

Construction[xx(J-02YS0,57mm)(ST)]CH
AWG23/1
Copper strand per conductor1 x 0,57 mm
Conductor insulationFoam/skin-PE 1,5 mm
ShieldingCopper braiding tin-plated 85% + AL-foil (total) and filler strand tin-plated AWG26 (0,4 mm) + AL-foil (wire pairs)
Shielding factor100 %
Temperature rangeFixed installation min. -30 °C
Temperature rangeFixed installation max. 70 °C
Jacket colorgray (RAL 7001)
Packagingper m
Capac. cond./cond. per 1 m45 pF
Capac. cond./shield. per 1 m86 pF
Cond. resistance per 1 km< 82 Ohm
Insulation resist. per 1 km100 GOhm
Surge impedance(+/-5 %) 110 Ohm
Damping per 100 m (20 °C)1 MHz: 2,5 dB
Damping per 100 m (20 °C)10 MHz: 6,3 dB
Damping per 100 m (20 °C)20 MHz: 8,6 dB
Damping per 100 m (20 °C)300 KHz: 1,4 dB
Damping per 100 m (20 °C)600 KHz: 2,0 dB

MODF 02MODF 03MODF 04MODF 05MODF 06MODF 08MODF 10MODF 12MODF 16MODF 20MODF 24MODF 32
2 x 2 x 0,57 mm3 x 2 x 0,57 mm4 x 2 x 0,57 mm5 x 2 x 0,57 mm6 x 2 x 0,57 mm8 x 2 x 0,57 mm10 x 2 x 0,57 mm12 x 2 x 0,57 mm16 x 2 x 0,57 mm20 x 2 x 0,57 mm24 x 2 x 0,57 mm32 x 2 x 0,57 mm
FRNC (test type C) 9,0 mmFRNC (test type C) 9,2 mmFRNC (test type C) 11,1 mmFRNC (test type C) 11,6 mmFRNC (test type C) 12,4 mmFRNC (test type C) 14,0 mmFRNC (test type C) 15,3 mmFRNC (test type C) 17,2 mmFRNC (test type C) 20,6 mmFRNC (test type C) 22,6 mmFRNC (test type C) 23,6 mmFRNC (test type C) 27,0 mm
0,25 kWh0,28 kWh0,40 kWh0,44 kWh0,49 kWh0,55 kWh0,65 kWh0,92 kWh1,30 kWh1,45 kWh1,53 kWh1,98 kWh
105 g112 g170 g191 g207 g275 g318 g387 g530 g580 g672 g866 g
100-1156-02100-1156-03100-1156-04100-1156-05100-1156-06100-1156-08100-1156-10100-1156-12100-1156-16100-1156-20100-1156-24100-1156-32



SOMMER CABLE - SC-LOGICABLE MODF 01

Construction[xx(J-02YS0,57mm)(ST)]CH
Jacket, diameterFRNC (test type C) 5,5 mm
AWG23/1
Conductor insulationFoam/skin-PE 1,5 mm
ShieldingFiller strand tin-plated AWG26 (0.4 mm) + AL-foil (wire pairs)
Shielding factor100 %
Temperature rangeFixed installation min. -30 °C
Temperature rangeFixed installation max. 70 °C
Packagingper m
Inner conductors1 x 2 x 0,57 mm
Copper strand per conductor1 x 0,57 mm
Fire load per m0,05 kWh
Weight per 1 m18 g
Capac. cond./cond. per 1 m45 pF
Capac. cond./shield. per 1 m86 pF
Cond. resistance per 1 km< 82 Ohm
Insulation resist. per 1 km100 GOhm
Surge impedance(+/-5 %) 110 Ohm
Damping per 100 m (20 °C)300 KHz: 1,4 dB
Damping per 100 m (20 °C)600 KHz: 2,0 dB
Damping per 100 m (20 °C)1 MHz: 2,5 dB
Damping per 100 m (20 °C)10 MHz: 6,3 dB
Damping per 100 m (20 °C)20 MHz: 8,6 dB
gray (RAL 7001)
100-1156-01