| SOMMER CABLE - SC-STRATOS |
| Construction | (LIHS09YHS1x0,34mm2)DY |
| Jacket, diameter | PVC 8,5 mm |
| AWG | 22 |
| No. of inner conductors | 1 x 0,34 mm2 |
| Copper strand per conductor | 7 x 0,25 mm |
| Conductor insulation | PE/PP mm |
| Shielding | copper braided shielding + semiconductor |
| Shielding factor | 100 % |
| Temperature range | min. -20 °C |
| Temperature range | max. 80 °C |
| Fire load per m | 0,25 kWh |
| Weight per 1 m | 55 g |
| Packaging | per m |
| Capac. cond./shield. per 1 m | 75 pF |
| Cond. resistance per 1 km | < 53 Ohm |
| Insulation resist. per 1 km | > 1 GOhm |
| slate | |
| SOMMER CABLE - SC-ALBEDO MKII |
| Construction | (2LI2Y0.20mm2)(ST)DY |
| Jacket, diameter | PVC 5,9 mm |
| AWG | 24 |
| No. of inner conductors | 2 x 0,20 mm2 |
| Copper strand per conductor | 102 x 0,05 mm |
| Conductor insulation | PP |
| Shielding | copper spiral shielding + AL/PT-foil |
| Shielding factor | 100 % |
| Temperature range | min. -30 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,13 kWh |
| Weight per 1 m | 32 g |
| Packaging | per m |
| Capac. cond./cond. per 1 m | 65 pF |
| Capac. cond./shield. per 1 m | 110 pF |
| Cond. resistance per 1 km | < 148 Ohm |
| Shield. resistance per 1 km | 30 Ohm |
| Insulation resist. per 1 km | > 1 GOhm |
| green | |
| SOMMER CABLE - SC-AQUILA CONTROL |
| Jacket, outer dimension | PVC 21,0 x 4,5 mm |
| AWG | 26 |
| No. of conductors | 2 x control 0,14 mm2 + 4 x 0,14 mm2 |
| Copper strand per conductor | 18 x 0,10 mm |
| Conductor insulation | PE 2,2 mm |
| Shielding | copper braiding + polyester-foil |
| Temperature range | min. -20 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,44 kWh |
| Weight per 1 m | 124 g |
| Packaging | 50 m roll |
| Capac. cond./shield. per 1 m | 60 pF |
| Cond. resistance per 1 km | 149 Ohm |
| Insulat. resistance per 1 km | > 10 MOhm |
| aqua blue | |
| SOMMER CABLE - SC-CORONA |
| Construction | (LIHS09YHS1x0,50mm2)CY |
| Jacket, diameter | PVC 6,7 mm |
| AWG | 20 |
| Inner conductors | 1 x 0,50 mm2 |
| Copper strand per conductor | 28 x 0,15 mm |
| Conductor insulation | PE |
| Shielding | copper braided shielding + semiconductor |
| Shielding factor | 100 % |
| Temperature range | min. -40 °C |
| Temperature range | max. 80 °C |
| Fire load per m | 0,25 kWh |
| Weight per 1 m | 55 g |
| Packaging | 50 m roll, per m |
| Capac. cond./shield. per 1 m | 78 pF |
| Cond. resistance per 1 km | < 36 Ohm |
| Insulat. resistance per 1 km | > 20 MOhm |
| transparent | |