| Construction | [LIY0,18mm2(ST)CY+(2LIY0,14mm2)DY+(3LIY1,5mm2)Y]Y |
| Inner conductors | (video) 1 x 0,18 mm |
| Jacket, diameter | PVC (power) 6,7 mm |
| Jacket, diameter | TPE (video) 3,3 mm |
| Jacket, diameter | TPE (audio) 2,4 mm |
| AWG | (video) 22 |
| AWG | (audio) 26 |
| No. of inner conductors | (audio) 2 x 0,14 mm2 |
| No. of inner conductors | (power) 3 x 1,5 mm2 |
| Inner conductors, diameter | (video) 0,48 mm |
| Copper strand per cond. (video) | tin-plated 7 x 0,18 mm |
| Copper strand per conductor (audio) | 18 x 0,10 mm |
| Conductor insulation | Foam/skin-PE (video) 2,2 mm |
| Shielding | copper braiding 90 % |
| Shielding factor | 90 % |
| Temperature range | min. -25 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,74 kWh |
| Weight per 1 m | 180 g |
| Packaging | per m |
| Matching plug | NBTC75BVX6 |
| Matching plug | BNC0.4/2.5-T |
| Capac. cond./cond. per 1 m | (audio) 78 pF |
| Capac. cond./shield. per 1 m | (video) 55 pF |
| Capac. cond./shield. per 1 m | (audio) 120 pF |
| Surge impedance | (+/-1 %) 75 Ohm |
| Damping per 100 m (20 °C) | 5 MHz: 4,3 dB |
| Damping per 100 m (20 °C) | 10 MHz: 6,2 dB |
| Damping per 100 m (20 °C) | 50 MHz: 15,0 dB |
| Damping per 100 m (20 °C) | 100 MHz: 21,2 dB |
| Damping per 100 m (20 °C) | 1500 MHz: 64,1 dB |
| Damping per 100 m (20 °C) | 3000 MHz: 101,3 dB |
| Inner conductors | (video) 7 x 0,38 mm |
| Jacket, diameter | PVC 12,5 mm |
| AWG | (video) 27 |
| AWG | (audio) 26 |
| AWG | (control) 26 |
| AWG | (control shielded) 26 |
| AWG | (power) 15 |
| No. of inner conductors | (audio) 3 x 2 x 0,14 mm2 |
| No. of inner conductors | (power) 2 x 1,5 mm2 |
| No. of inner conductors | (control) 5 x 0,14 mm2 |
| No. of inner conductors | (control shielded) 1 x 0,14 mm2 |
| Copper strand per conductor | (video) tin-plated 7 x 0,127 mm |
| Copper strand per conductor | (power) tin-plated 84 x 0,15 mm |
| Copper strand per conductor | (audio, control) tin-plated 18 x 0,10 mm |
| Conductor insulation | PVC + Skin PE (video) 1,60 mm |
| Conductor insulation | PVC (audio, control, power) mm |
| Shielding | copper braiding overall shielding tin-plated 85 % |
| Shielding | copper braided shielding tin-plated, 95 % (audio, control, video) |
| Shielding factor | 85 % |
| Temperature range | min. -20 °C |
| Temperature range | max. 70 °C |
| Fire load per m | 0,90 kWh |
| Weight per 1 m | 280 g |
| Packaging | per m |
| Matching plug | BNC0.3/1.8 |
| Matching plug | NBTC75BFI4 |
| Capac. cond./cond. per 1 m | (audio) 240 pF |
| Capac. cond./shield. per 1 m | (video) 65 pF |
| Capac. cond./shield. per 1 m | (audio) 380 pF |
| Capac. cond./shield. per 1 m | (control) 320 pF |
| Cond. resistance per 1 km | (video) 48 Ohm |
| Surge impedance | (+/-5 %) 75 Ohm |
| Damping per 100 m (20 °C) | 1 MHz: 2,4 dB |
| Damping per 100 m (20 °C) | 10 MHz: 6,8 dB |
| Damping per 100 m (20 °C) | 50 MHz: 14,1 dB |
| Damping per 100 m (20 °C) | 100 MHz: 20,0 dB |
| Damping per 100 m (20 °C) | 150 MHz: 25,7 dB |