Bulk Cables - Audio  |  Microphone Cable


SOMMER CABLE - SC-CLUB SERIES MKII

Construction(2LI2Y0,34mm2)CY
AWG22
No. of inner conductors2 x .34 mm2
Copper strand per conductor19 x .0059 inch
Conductor insulationPE .059 inch
Shieldingcopper braided shielding with 0.10 mm indiv. strand
Shielding factor95 %
Temperature rangemin. -13 °F
Temperature rangemax. 158 °F
Fire load per inch.067 kWh
Weight per 1000 ft37.5 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft17.7 pF
Capac. cond./shield. per 1 ft35.1 pF
Cond. resistance per 1000 ft< 16.8 Ohm
Shield. resistance per 1000 ft7.6 Ohm
Insulation resist. per 1000 ft> .30 GOhm
Surge impedanceapprox. 100 Ohm
PVC 0000 x .26 inchFRNC 0000 x .26 inchPVC 0000 x .26 inchPVC 0000 x .26 inchPVC 0000 x .26 inchPVC 0000 x .26 inch
blackblackblack, without imprintblueredtweed-yellow
---------------vintage tweed
200-0051200-0051F200-0051NE200-0052200-0053200-0057V



SOMMER CABLE - SC-STAGE 22 HIGHFLEX

Construction(2LI2Y0,22mm2)DY
Jacket, diameterPVC 0000 x .25 inch
AWG24
No. of inner conductors2 x .22 mm2
Copper strand per conductor28 x .0039 inch
Conductor insulationPE .055 inch
Shieldingcopper spiral shielding with 0.10 mm indiv. strand
Shielding factor99 %
Temperature rangemin. -4 °F
Temperature rangemax. 158 °F
Fire load per inch.067 kWh
Weight per 1000 ft36.9 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft20.7 pF
Capac. cond./shield. per 1 ft39.6 pF
Cond. resistance per 1000 ft< 26.5 Ohm
Shield. resistance per 1000 ft< 9.1 Ohm
Insulation resist. per 1000 ft> .30 GOhm
Surge impedanceapprox. 100 Ohm
blackblack, without imprintblueredgreenicy grayyellowpurple
200-0001200-0001NE200-0002200-0003200-0004200-0006200-0007200-0008



SOMMER CABLE - SC-PRIMUS

Construction(2LI2Y0,50mm2)(ST)DY
AWG20
No. of inner conductors2 x .5 mm2
Copper strand per conductor28 x .0059 inch
Conductor insulationPE .065 inch
Shieldingcopper spiral sleeve tin-plated + metalic fleece
Shielding factor100 %
Temperature rangemin. -13 °F
Temperature rangemax. 158 °F
Fire load per inch.070 kWh
Weight per 1000 ft35.5 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft24.4 pF
Capac. cond./shield. per 1 ft44.2 pF
Cond. resistance per 1000 ft11.3 Ohm
Shield. resistance per 1000 ft8.2 Ohm
Insulation resist. per 1000 ft> .30 GOhm
PVC 0000 x .26 inchFRNC 0000 x .26 inchPVC 0000 x .26 inch
blackblackblue
200-0151200-0151F200-0152



SOMMER CABLE - SC-SOURCE MKII HIGHFLEX

Construction(2LI2Y0,25mm2)(ST)DY
AWG23
No. of inner conductors2 x .25 mm2
Conductor insulationPE .061 inch
Shielding factor100 %
Temperature rangemin. -13 °F
Temperature rangemax. 158 °F
Fire load per inch.064 kWh
Weight per 1000 ft32.2 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft18.3 pF
Capac. cond./shield. per 1 ft33.5 pF
Cond. resistance per 1000 ft< 23.8 Ohm
Shield. resistance per 1000 ft7.6 Ohm
Insulat. resistance per 1000 ft> 61.0 MOhm
PVC 0000 x .26 inchFRNC (test type C) 0000 x .26 inchPVC 0000 x .26 inchPVC 0000 x .26 inchPVC 0000 x .26 inchPUR halogen-free 0000 x .26 inch
128 x .0020 inch32 x .0039 inch128 x .0020 inch128 x .0020 inch128 x .0020 inch---
copper spiral shielding tin-plated 95 % + AL-fleececopper spiral shielding tin-plated 95 % + AL-foilcopper spiral shielding tin-plated 95 % + AL-fleececopper spiral shielding tin-plated 95 % + AL-fleececopper spiral shielding tin-plated 95 % + AL-fleececopper spiral shielding tin-plated 95 % + AL-fleece
blackblackblueblueredblack
---------halogen-free------
200-0101200-0101F200-0102200-0102H200-0103201-0101



SOMMER CABLE - SC-GALILEO

Construction(2LI2Y0.38mm2)YDDY
Jacket, diameterPVC 0000 x .28 inch
AWG21
No. of inner conductors2 x .38 mm2
Copper strand per conductor48 x .0039 inch
Conductor insulationPE .061 inch
Shielding factor100 %
Temperature rangemin. -22 °F
Temperature rangemax. 158 °F
Fire load per inch.067 kWh
Weight per 1000 ft40.2 lbs
Packaging328 ft roll
Capac. cond./cond. per 1 ft15.2 pF
Capac. cond./shield. per 1 ft30.5 pF
Cond. resistance per 1000 ft< 15.8 Ohm
Shield. resistance per 1000 ft6.1 Ohm
Insulation resist. per 1000 ft> .30 GOhm
Surge impedance38 Ohm

238238 Plus
double copper spiral, counter-rotatingdouble copper spiral, counter-rotating + polyester tape
blackblack
200-0251200-0271



SOMMER CABLE - SC-SYMBIOTIC

Construction(2LI2Y0,20mm2)YDDY
AWG24
No. of inner conductors2 x .2 mm2
Copper strand per conductor102 x .0020 inch
Conductor insulationPE .051 inch
Shieldingdouble copper spiral, counter-rotating
Shielding factor100 %
Temperature rangemin. -22 °F
Temperature rangemax. 158 °F
Fire load per inch.040 kWh
Weight per 1000 ft25.5 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft29.0 pF
Capac. cond./shield. per 1 ft39.6 pF
Cond. resistance per 1000 ft< 28.7 Ohm
Insulat. resistance per 1000 ft> 61.0 MOhm
PVC 0000 x .20 inchTPE 0000 x .20 inch
black, PVCblack
200-0601200-0601H



SOMMER CABLE - SC-SYMBIOTIC 3

Construction(3LI2Y0,20mm2)YDDY
Jacket, diameterTPE 0000 x .20 inch
AWG24
No. of inner conductors3 x .2 mm2
Copper strand per conductor102 x .0020 inch
Conductor insulationPP .051 inch
Shieldingdouble copper spiral shielding, counter-rotating
Shielding factor100 %
Temperature rangemin. -22 °F
Temperature rangemax. 158 °F
Fire load per inch.034 kWh
Weight per 1000 ft36.9 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft29.0 pF
Capac. cond./shield. per 1 ft39.6 pF
Cond. resistance per 1000 ft< 27.4 Ohm
Shield. resistance per 1000 ft7.6 Ohm
Insulat. resistance per 1000 ft> 61.0 MOhm
black
200-0601H3



SOMMER CABLE - SC-SQUARE 4-CORE MKII HIGHFLEX

Construction(4LI2Y0,20mm2)(ST)DY
Jacket, diameterPVC 0000 x .26 inch
AWG24
No. of inner conductors4 x .2 mm2
Copper strand per conductor102 x .0020 inch
Conductor insulationPE
Shieldingcopper spiral shielding + conductive fleece-foil
Shielding factor100 %
Temperature rangemin. -13 °F
Temperature rangemax. 158 °F
Fire load per inch.067 kWh
Weight per 1000 ft35.5 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft19.8 pF
Capac. cond./cond. per 1 ft(Crossover) 11.9 pF
Capac. cond./shield. per 1 ft36.6 pF
Capac. cond./shield. per 1 ft(Crossover) 23.8 pF
Cond. resistance per 1000 ft< 29.9 Ohm
Shield. resistance per 1000 ft< 6.1 Ohm
Insulat. resistance per 1000 ft> 61.0 MOhm
Surge impedance< 95 Ohm
black
200-0301



SOMMER CABLE - SC-OCTAVE TUBE

Construction(5LI2Y0,14mm2+2LI2Y0,50mm2)(ST)DY
Jacket, diameterPVC 0000 x .26 inch
AWG(audio) 26
AWG(control) 20
No. of inner conductors(audio) 5 x .14 mm2
No. of inner conductors(control) 2 x .5 mm2
Copper strand per conductor(audio) 72 x .0020 inch
Copper strand per conductor(control) 64 x .0039 inch
Conductor insulationPE
Shieldingcopper spiral shielding tin-plated + AL-fleece
Shielding factor100 %
Temperature rangemin. -13 °F
Temperature rangemax. 158 °F
Fire load per inch.061 kWh
Weight per 1000 ft44.9 lbs
Packagingper ft
Capac. cond./cond. per 1 ft21.0 pF
Capac. cond./shield. per 1 ft36.6 pF
Cond. resistance per 1000 ft(audio) 42.7 Ohm
Cond. resistance per 1000 ft(control) 11.9 Ohm
Shield. resistance per 1000 ft< 5.2 Ohm
Insulat. resistance per 1000 ft> 61.0 MOhm
gray
200-0186



SOMMER CABLE - SC-CAPTAIN FLEXIBLE

Construction(2LIY0,22mm2)DY
Jacket, diameterPVC 0000 x .26 inch
AWG24
Inner conductors2 x .22 mm2
Copper strand per conductor28 x .0039 inch
Conductor insulationPE .055 inch
Shieldingcopper spiral shielding with 0.10 mm indiv. strand
Shielding factor99 %
Temperature rangemin. -4 °F
Temperature rangemax. 158 °F
Fire load per inch.067 kWh
Weight per 1000 ft36.9 lbs
Packaging328/1640 ft roll
Capac. cond./cond. per 1 ft21.0 pF
Capac. cond./shield. per 1 ft40.2 pF
Cond. resistance per 1000 ft< 26.5 Ohm
Shield. resistance per 1000 ft< 9.1 Ohm
Insulation resist. per 1000 ft> .30 GOhm
Surge impedanceapprox. 100 Ohm
olive green
200-008M