| Construction | LI2Y(xPSTY) x2x0,22mm² + LIY4x2,5mm² + LIYY3x1,5ST-Y |
| Jacket, diameter | PVC 0000 x .94 inch |
| AWG | (audio) 24 |
| AWG | (speaker/control wire) 13 |
| AWG | (power) 15 |
| Inner conductors | (Audio) 16 x 2 x .22 mm2 |
| No. of inner conductors | (speaker/control wire) 4 x 2.5 mm2 |
| No. of inner conductors | (power) 3 x 1.5 mm2 |
| Copper strand per conductor | (speaker) 50 x .0098 inch |
| Copper strand per conductor | (audio) 7 x .0079 inch |
| Conductor insulation | Foam/skin-PE (audio) |
| Shielding | AL/PT-foil + filler strand (audio) + AL/PT-foil overall shielding + filler strand |
| Temperature range | min. -22 °F |
| Temperature range | max. 158 °F |
| Fire load per inch | .66 kWh |
| Weight per 1000 ft | 469 lbs |
| Jacket color | black, mat |
| Packaging | per ft |
| Capac. cond./cond. per 1 ft | (audio) 19.8 pF |
| Capac. cond./shield. per 1 ft | (audio) 39.6 pF |
| Cond. resistance per 1000 ft | (audio) < 42.1 Ohm |
| Cond. resistance per 1000 ft | (speaker) < 2.3 Ohm |
| Shield. resistance per 1000 ft | (audio) 22.9 Ohm |
| Insulat. resistance per 1000 ft | > 6.1 MOhm |
| Surge impedance | (audio) 110 Ohm |
| Operation voltage (audio) | max. 300 V |
| Operation voltage (speaker) | max. 500 |
| Test voltage | (speaker) 2.5 kV |
| Test voltage | (audio) 1.5 kV |