| SOMMER CABLE - SC-SEMICOLON 2 AES/EBU PATCH |
| Construction | (2LI2Y0,22mm2)(ST)DY |
| AWG | 24 |
| No. of inner conductors | 2 x .22 mm2 |
| Copper strand per conductor | 7 x .0079 inch |
| Conductor insulation | Foam/skin-PE .051 inch |
| Shielding | copper spiral shielding + AL/PT-foil |
| Shielding factor | 100 % |
| Temperature range | min. -13 °F |
| Temperature range | max. 158 °F |
| Fire load per inch | .040 kWh |
| Weight per 1000 ft | 22.1 lbs |
| Packaging | 328/1640 ft roll |
| Capac. cond./cond. per 1 ft | 13.7 pF |
| Cond. resistance per 1000 ft | 24.4 Ohm |
| Insulation resist. per 1000 ft | > .30 GOhm |
| Surge impedance | 110 Ohm |
| Damping per 100 ft (68 °F) | 1 MHz: .67 dB |
| Damping per 100 ft (68 °F) | 10 MHz: 2.1 dB |
| Damping per 100 ft (68 °F) | 3 MHz: 1.2 dB |
| PVC 0000 x .20 inch | FRNC 0000 x .20 inch | |
| blue | blue | |
| --- | FRNC | |
| SOMMER CABLE - SC-PEACOCK AES/EBU |
| Construction | 2[(2LI2Y0,22mm2)DY] |
| Jacket, outer dimension | S-PVC .18 x .36 inch |
| AWG | 24 |
| Inner conductors | 2 x 2 x .22 mm2 |
| Copper strand per conductor | 28 x .0039 inch |
| Conductor insulation | Foam/skin-PE .051 inch |
| Shielding | copper spiral shielding |
| Shielding factor | 95 % |
| Temperature range | min. -22 °F |
| Temperature range | max. 158 °F |
| Fire load per inch | .055 kWh |
| Weight per 1000 ft | 32.8 lbs |
| Packaging | 328 ft roll |
| Capac. cond./cond. per 1 ft | 21.3 pF |
| Capac. cond./shield. per 1 ft | 38.1 pF |
| Cond. resistance per 1000 ft | < 27.4 Ohm |
| Shield. resistance per 1000 ft | < 11.0 Ohm |
| Insulat. resistance per 1000 ft | > 152 MOhm |
| Surge impedance | 110 Ohm |
| blue | |
| SOMMER CABLE - SC-BINARY 234 AES/EBU MKII |
| Construction | (2LI2Y0,34mm2)(ST)DY |
| AWG | 22 |
| No. of inner conductors | 2 x .34 mm2 |
| Copper strand per conductor | 19 x .0059 inch |
| Conductor insulation | Foam/skin-PE .059 inch |
| Shielding | copper spiral shielding + aluminum steamed fleece |
| Shielding factor | 100 % |
| Temperature range | min. -13 °F |
| Temperature range | max. 158 °F |
| Weight per 1000 ft | 33.5 lbs |
| Packaging | 328 ft roll |
| Capac. cond./cond. per 1 ft | < 19.2 pF |
| Capac. cond./shield. per 1 ft | 35.1 pF |
| Cond. resistance per 1000 ft | 16.2 Ohm |
| Shield. resistance per 1000 ft | 8.5 Ohm |
| Insulation resist. per 1000 ft | > .30 GOhm |
| Surge impedance | 110 Ohm |
| PVC 0000 x .25 inch | FRNC (test type C) 0000 x .22 inch | PVC 0000 x .25 inch | PVC 0000 x .25 inch | PUR-Blend 0000 x .25 inch | |
| .052 kWh | .070 kWh | .052 kWh | .052 kWh | .052 kWh | |
| black | black | blue | gray | black | |
| SOMMER CABLE - SC-BINARY 434 DMX512 |
| Construction | [2(2LI2YS0,34mm2)(ST)]CY |
| AWG | 22 |
| No. of inner conductors | 4 x .34 mm2 |
| Copper strand per conductor | 7 x .0098 inch |
| Conductor insulation | PE .067 inch |
| Shielding | copper-cross mesh, tin-plated + AL/PT-foil |
| Shielding factor | 100 % |
| Temperature range | min. -13 °F |
| Temperature range | max. 158 °F |
| Fire load per inch | .067 kWh |
| Weight per 1000 ft | 43.6 lbs |
| Packaging | 328 ft roll |
| Capac. cond./cond. per 1 ft | 19.8 pF |
| Capac. cond./shield. per 1 ft | 74.7 pF |
| Cond. resistance per 1000 ft | 16.2 Ohm |
| Shield. resistance per 1000 ft | 4.6 Ohm |
| Insulation resist. per 1000 ft | > 1.5 GOhm |
| Surge impedance | 110 Ohm |
| Transmission speed | acc. to EIA 485 standard 256 Kbs |
| PVC 0000 x .28 inch | PE 0000 x .28 inch | PVC 0000 x .28 inch | PUR-Blend 0000 x .28 inch | |
| black | black | gray | black | |
| --- | PE | --- | PUR-Blend | |
| SOMMER CABLE - SC-BINARY 422 TP DMX512 |
| Construction | [2(2LI2YS0,22mm2)(ST)]CY |
| Jacket, diameter | S-PVC 0000 x .31 inch |
| AWG | 24 |
| Inner conductors | 4 x .22 mm2 |
| Copper strand per conductor | 7 x .0079 inch |
| Conductor insulation | Foam/skin-PE .061 inch |
| Shielding | copper braiding tin-plated + 2 x AL-PT-foil |
| Shielding factor | 100 % |
| Temperature range | min. -13 °F |
| Temperature range | max. 158 °F |
| Fire load per inch | .076 kWh |
| Weight per 1000 ft | 50.9 lbs |
| Packaging | 328 ft roll |
| Capac. cond./cond. per 1 ft | 13.7 pF |
| Capac. cond./shield. per 1 ft | 33.5 pF |
| Cond. resistance per 1000 ft | < 26.5 Ohm |
| Shield. resistance per 1000 ft | 4.6 Ohm |
| Insulat. resistance per 1000 ft | > 30.5 MOhm |
| Surge impedance | 110 Ohm |
| Transmission speed | acc. to EIA 485 standard 256 Kbs |
| black | blue | |