TECHNICAL DATA: |
| Construction | [xx(2LI2Y0,25mm2)DH]CH |
| Jacket, diameter | FRNC (test type C) 0000 x 1.0 inch |
| AWG | 23 |
| No. of inner conductors | 32 x 2 x .25 mm2 |
| Copper strand per conductor | 32 x .0039 inch |
| Conductor insulation | Foam/skin-PE .053 inch |
| Shielding | copper spiral + copper braiding overall shielding |
| Shielding factor | copper-spiral 95 % |
| Shielding factor | Cu-braiding 90 % |
| Temperature range | min. -40 °F |
| Temperature range | max. 185 °F |
| Fire load per inch | .80 kWh |
| Weight per 1000 ft | 504 lbs |
| Jacket color | dark blue |
| Packaging | per ft |
ELECTRICAL DATA: |
| Capac. cond./cond. per 1 ft | 18.3 pF |
| Capac. cond./shield. per 1 ft | 32.0 pF |
| Cond. resistance per 1000 ft | < 27.4 Ohm |
| Insulation resist. per 1000 ft | > .30 GOhm |
| Surge impedance at 1.0 Mhz | 110 Ohm |
| Damping per 100 ft (68 °F) | 1 MHz: .53 dB |
| Damping per 100 ft (68 °F) | 5 MHz: 2.1 dB |
| Damping per 100 ft (68 °F) | 10 MHz: 3.4 dB |
| Damping per 100 ft (68 °F) | 20 MHz: 5.4 dB |
| Damping per 100 ft (68 °F) | 40 MHz: 8.9 dB |
| Damping per 100 ft (68 °F) | 60 MHz: 11.9 dB |
| Damping per 100 ft (68 °F) | 80 MHz: 14.7 dB |
| Damping per 100 ft (68 °F) | 100 MHz: 17.3 dB |
ORDER DATA: |
| Order No. | 100-0302-32 |
| Rec. price | on request |