SOMMER CABLE - SC-MONOLITH POWER DMX 1 Compact
   
  
When the lights start to dance...the show begins! There also is a lot of technology behind this performance, SOMMER Cables play a great role here! The power for the lights and the control signals for the movement must be transmitted through the cables. Both are paired in a robust cable jacket, providing the input for the light mixing board and other DMX 512-dependent control units.
The SC-MONOLITH POWER/DMX holds one power cable 3 x 1.5 mm˛ and one (SC-MONOLITH 1), two (SC-MONOLITH 2) or four (SC-MONOLITH 4) DMX 512-cables. The SC-MONOLITH 4 has two DMX-cables available for transmission of intercom signals. Each DMX-wire pair is shielded with a tin-plated copper spiral and both wire pairs are numbered for better identification. The SC-MONOLITH 8 is designed for large events and holds 8 cables with return channels (8 x 4 x 0.008 in). The power cable is designed in compliance with VDE and has its own jacket for added safety.
The AES/EBU-cable can also be used as a microphone cable or as an infeed cable for active speaker systems.
HV-type with 3 x 2.5 mm˛ power cable!
Cable includes power, DMX and CAT, see next page.
THE ADVANTAGES: - Parallel controls for light mixing boards via power line and DMX-signal via cable
- Very flexible and enormously treadable due to a jacket made of cotton and viscose
- Very good paired shielding of the DMX-cables due to tinplated copper spiral shielding
THE APPLICATION: - Controls for DMX-light mixing board (surge impedance of 110 Ohm)
- Analog + digital audio multipair with power supply
TECHNICAL DATA: | | Construction | [(3LIY1,5mm2)Y+xx(2LI2Y0,25mm2)DY]VLY | | Power infeed | 3 x 1.5 mm2 | | Jacket, diameter, total | PVC .41 inch | | AWG | 23 | | No. of inner conductors | 1 x 2 x .25 mm2 | | Diameter power infeed | single wire 0000 inch | | Diameter DMX cable | .15 inch | | Copper strand per conductor | (DMX) 7 x .0079 inch | | Shielding (data) | cross mesh, tin-plated | | Shielding factor (audio) | 90 % | | Temperature range | min. -22 °F | | Temperature range | max. 158 °F | | Fire load per inch | .16 kWh | | Weight per 1000 ft | 127 lbs | | Jacket color | black | | Packaging | per ft | ELECTRICAL DATA: | | Capac. cond./cond. per 1 ft | 15.8 pF | | Capac. cond./shield. per 1 ft | 27.1 pF | | Cond. resistance per 1000 ft | < 24.4 Ohm | | Insulat. resistance per 1000 ft | > 6.1 MOhm | | Surge impedance, data | (+/- 5 %) 110 Ohm | ORDER DATA: | | Order No. | 502-0051-1 | | Rec. price | on request |

v2010-JUN-14 |