TECHNICAL DATA: |
| Construction | J02Y(ST)CY 4x2x0,51mm/300MHz |
| Jacket, diameter | PVC 0000 x .24 inch |
| AWG | 24 |
| Copper strand per conductor | 1 x .020 inch |
| Conductor insulation | Foam/skin-PE .040 inch |
| Shielding | AL/PT-foil + filler strand |
| Shielding factor | 100 % |
| Temperature range | min. -4 °F |
| Temperature range | max. 167 °F |
| Fire load per inch | .058 kWh |
| Weight per 1000 ft | 33.5 lbs |
| Packaging | 328/1640 ft roll |
| Matching plug | RJ45CMXL-GR |
| Color | gray |
| Type | FTP |
| Type | install |
ELECTRICAL DATA: |
| Capac. cond./cond. per 1 ft | 14.9 pF |
| Insulation resist. per 1000 ft | > 1.5 GOhm |
| Surge impedance | (+/-15 Ohm) 100 Ohm |
| Loop resistance | 5.1 Ohm/ft |
| Maximum delay | @ 100 MHz (per 328 ft) 500 ns |
| Max. section length | 328 ft |
| @100 MHz (per 328 ft) 20 ns |
| Damping per 100 ft (68 °F) | 1 MHz: .58 dB |
| Damping per 100 ft (68 °F) | 16 MHz: 2.3 dB |
| Damping per 100 ft (68 °F) | 100 MHz: 5.7 dB |
| Damping per 100 ft (68 °F) | 155 MHz: 7.6 dB |
| Damping per 100 ft (68 °F) | 300 MHz: 9.8 dB |
ORDER DATA: |
| Order No. | 580-0056 |
| Rec. price | on request |