Dance at all parties...
this cable can do it. Just look at the many applications! And our RG cables are famous for their aging resistance and durability. RG (radio guide) cables have either one or two cross mesh screens, designed according to the American MIL-C-17 standard. This standard originally developed for the army, guarantees excellent and consistent manufacturing quality and durability. RG cables have been created for a vast number of applications in high frequency technology, electronics, and data transmission.
Advantages:
- Low Loss
- Extremely long life due to age-resistant jacket
- Consistent and precise electrical values
- Easy handling
- Suitable for all standardised connectors
Application:
- Data transmission
- HF technology
- Antenna construction
- For fixed installations
- Computer technology
| Article number: | 600-0291 |
|---|---|
| Name: | Coaxflex 10 / RG213 LL |
| EAN: | 4049371494496 |
| Properties: | Analog, OFC oxygen free copper |
| Application area: | ELA 100 V, Installation, Studio / Broadcast |
| Application: | HF400Flex, RG/U Coax |
| Colour: | black |
| Jacket material: | PVC |
| Jacket Ø [mm]: | 10.30 |
| Jacket Ø ["]: | 0.4055 |
| Number of Channels (video): | 1 |
| Inner conductor: | 1 |
| Inner conductor (video): | 1 |
| Inner conductor (video) [mm²]: | 4,98 |
| Inner conductor (video) [sqin]: | 0.0077 |
| Inner conductor Ø (video) [mm]: | 2,52 |
| Inner conductor Ø (video) ["]: | 0.0992 |
| AWG (video): | 10 |
| Shielding: | Copper braiding tin-plated + AL / PT foil |
| Shielding factor [%]: | 100 |
| Copper strands (video): | 7 |
| Copper strand Ø (video) [mm]: | 0,95 |
| Copper strand Ø (video) ["]: | 0.0374 |
| Conductor insulation material: | Gas-injected Foam / Skin-PE |
| Conductor insulation Ø [mm]: | 7,25 |
| Conductor insulation Ø ["]: | 0.2854 |
| Weight per 1 m [g]: | 144.5 |
| Style variant: | round |
| Packing: | 100 m ring, 500 m spool |
| Velocity factor: | 0.84 |
| Temperature min. [°C]: | -30 |
| Temperature max. [°C]: | 70 |
| RG-Type: | HF400Flex |
| Width [mm]: | 10,3 |
| Width ["]: | 0.4055 |
| Height [mm]: | 10,3 |
| Height ["]: | 0.4055 |
| Capacity wire/electic screen at 1m (video) [pF]: | 80 |
| Capacity wire/electic screen at 1 ft. (video) [pF]: | 24.384 |
| Damping at 5 MHz (100m & 20° C) [dB]: | 1,1 |
| Damping at 5 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 0.3353 |
| Damping at 50 MHz (100m & 20° C) [dB]: | 3 |
| Damping at 50 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 0.9144 |
| Damping at 100 MHz (100m & 20° C) [dB]: | 4,2 |
| Damping at 100 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 1.2802 |
| Damping at 200 MHz (100m & 20° C) [dB]: | 5,8 |
| Damping at 200 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 1.7678 |
| Damping at 470 MHz (100m & 20° C) [dB]: | 9,2 |
| Damping at 470 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 2.8042 |
| Damping at 862 MHz (100m & 20° C) [dB]: | 13 |
| Damping at 862 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 3.9624 |
| Damping at 1000 MHz (100m & 20° C) [dB]: | 14,1 |
| Damping at 1000 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 4.2977 |
| Damping at 1485 MHz (100m & 20° C) [dB]: | 17,3 |
| Damping at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 5.273 |
| Damping at 1750 MHz (100m & 20° C) [dB]: | 19 |
| Damping at 1750 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 5.7912 |
| Damping at 2150 MHz (100m & 20° C) [dB]: | 21,4 |
| Damping at 2150 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 6.5227 |
| Damping at 3000 MHz (100m & 20° C) [dB]: | 25,8 |
| Damping at 3000 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 7.8638 |
| Impedance [Ω]: | 50 |
| Conductor resistance per 1 km [Ω]: | 4 |
| Conductor resistance per 1000 ft. [Ω]: | 1.2192 |
| Shield. resistance per 1 km [Ω]: | 7,4 |
| Shield. resistance per 1000 ft. [Ω]: | 2.2555 |
| Old article number: | 999-0001-564 |
| BPVo-Euroclass: | Eca |
| Article number: | 600-0291 |
|---|---|
| Name: | Coaxflex 10 / RG213 LL |
| EAN: | 4049371494496 |
| Properties: | Analog, OFC oxygen free copper |
| Application area: | ELA 100 V, Installation, Studio / Broadcast |
| Application: | HF400Flex, RG/U Coax |
| Colour: | black |
| Jacket material: | PVC |
| Jacket Ø [mm]: | 10.30 |
| Jacket Ø ["]: | 0.4055 |
| Number of Channels (video): | 1 |
| Inner conductor: | 1 |
| Inner conductor (video): | 1 |
| Inner conductor (video) [mm²]: | 4,98 |
| Inner conductor (video) [sqin]: | 0.0077 |
| Inner conductor Ø (video) [mm]: | 2,52 |
| Inner conductor Ø (video) ["]: | 0.0992 |
| AWG (video): | 10 |
| Shielding: | Copper braiding tin-plated + AL / PT foil |
| Shielding factor [%]: | 100 |
| Copper strands (video): | 7 |
| Copper strand Ø (video) [mm]: | 0,95 |
| Copper strand Ø (video) ["]: | 0.0374 |
| Conductor insulation material: | Gas-injected Foam / Skin-PE |
| Conductor insulation Ø [mm]: | 7,25 |
| Conductor insulation Ø ["]: | 0.2854 |
| Weight per 1 m [g]: | 144.5 |
| Style variant: | round |
| Packing: | 100 m ring, 500 m spool |
| Velocity factor: | 0.84 |
| Temperature min. [°C]: | -30 |
| Temperature max. [°C]: | 70 |
| RG-Type: | HF400Flex |
| Width [mm]: | 10,3 |
| Width ["]: | 0.4055 |
| Height [mm]: | 10,3 |
| Height ["]: | 0.4055 |
| Capacity wire/electic screen at 1m (video) [pF]: | 80 |
| Capacity wire/electic screen at 1 ft. (video) [pF]: | 24.384 |
| Damping at 5 MHz (100m & 20° C) [dB]: | 1,1 |
| Damping at 5 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 0.3353 |
| Damping at 50 MHz (100m & 20° C) [dB]: | 3 |
| Damping at 50 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 0.9144 |
| Damping at 100 MHz (100m & 20° C) [dB]: | 4,2 |
| Damping at 100 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 1.2802 |
| Damping at 200 MHz (100m & 20° C) [dB]: | 5,8 |
| Damping at 200 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 1.7678 |
| Damping at 470 MHz (100m & 20° C) [dB]: | 9,2 |
| Damping at 470 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 2.8042 |
| Damping at 862 MHz (100m & 20° C) [dB]: | 13 |
| Damping at 862 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 3.9624 |
| Damping at 1000 MHz (100m & 20° C) [dB]: | 14,1 |
| Damping at 1000 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 4.2977 |
| Damping at 1485 MHz (100m & 20° C) [dB]: | 17,3 |
| Damping at 1485 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 5.273 |
| Damping at 1750 MHz (100m & 20° C) [dB]: | 19 |
| Damping at 1750 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 5.7912 |
| Damping at 2150 MHz (100m & 20° C) [dB]: | 21,4 |
| Damping at 2150 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 6.5227 |
| Damping at 3000 MHz (100m & 20° C) [dB]: | 25,8 |
| Damping at 3000 MHz (100 ft. & 20 °C / 68 °F) [dB]: | 7.8638 |
| Impedance [Ω]: | 50 |
| Conductor resistance per 1 km [Ω]: | 4 |
| Conductor resistance per 1000 ft. [Ω]: | 1.2192 |
| Shield. resistance per 1 km [Ω]: | 7,4 |
| Shield. resistance per 1000 ft. [Ω]: | 2.2555 |
| Old article number: | 999-0001-564 |
| BPVo-Euroclass: | Eca |
Coaxflex 10 / RG213 LL
RG/U Coax
Advantages:
- Low Loss
- Extremely long life due to age-resistant jacket
- Consistent and precise electrical values
- Easy handling
- Suitable for all standardised connectors
Application:
- Data transmission
- HF technology
- Antenna construction
- For fixed installations
- Computer technology
Technical Data:
- Article number: 600-0291
- Name: Coaxflex 10 / RG213 LL
- EAN: 4049371494496
- Properties: Analog
- Properties: OFC oxygen free copper
- Application area: ELA 100 V
- Application area: Studio / Broadcast
- Application area: Installation
- Application: RG/U Coax
- Colour: black
- Jacket material: PVC
- Jacket Ø: 10,30 mm
- Jacket Ø: 0.4055 "
- Number of Channels (video): 1
- Inner conductor: 1
- Inner conductor (video): 1
- Inner conductor (video): 4,98 mm²
- Inner conductor (video): 0.0077 sqin
- Inner conductor Ø (video): 2,52 mm
- Inner conductor Ø (video): 0.0992 "
- AWG (video): 10
- Shielding: Copper braiding tin-plated + AL / PT foil
- Shielding factor: 100 %
- Copper strands (video): 7
- Copper strand Ø (video): 0,95 mm
- Copper strand Ø (video): 0.0374 "
- Conductor insulation material: Gas-injected Foam / Skin-PE
- Conductor insulation Ø: 7,25 mm
- Conductor insulation Ø: 0.2854 "
- Weight per 1 m: 144.5 g
- UV-resistant: yes
- Style variant: round
- Packing: 500 m spool
- Packing: 100 m ring
- Velocity factor: 0,84
- Temperature min.: -30 °C
- Temperature max.: 70 °C
- Width: 10,3 mm
- Width: 0.4055 "
- Height: 10,3 mm
- Height: 0.4055 "
- Capacity wire/electic screen at 1m (video): 80 pF
- Capacity wire/electic screen at 1 ft. (video): 24.384 pF
- Damping at 5 MHz (100m & 20° C): 1,1 dB
- Damping at 5 MHz (100 ft. & 20 °C / 68 °F): 0.3353 dB
- Damping at 50 MHz (100m & 20° C): 3 dB
- Damping at 50 MHz (100 ft. & 20 °C / 68 °F): 0.9144 dB
- Damping at 100 MHz (100m & 20° C): 4,2 dB
- Damping at 100 MHz (100 ft. & 20 °C / 68 °F): 1.2802 dB
- Damping at 200 MHz (100m & 20° C): 5,8 dB
- Damping at 200 MHz (100 ft. & 20 °C / 68 °F): 1.7678 dB
- Damping at 470 MHz (100m & 20° C): 9,2 dB
- Damping at 470 MHz (100 ft. & 20 °C / 68 °F): 2.8042 dB
- Damping at 862 MHz (100m & 20° C): 13 dB
- Damping at 862 MHz (100 ft. & 20 °C / 68 °F): 3.9624 dB
- Damping at 1000 MHz (100m & 20° C): 14,1 dB
- Damping at 1000 MHz (100 ft. & 20 °C / 68 °F): 4.2977 dB
- Damping at 1485 MHz (100m & 20° C): 17,3 dB
- Damping at 1485 MHz (100 ft. & 20 °C / 68 °F): 5.273 dB
- Damping at 1750 MHz (100m & 20° C): 19 dB
- Damping at 1750 MHz (100 ft. & 20 °C / 68 °F): 5.7912 dB
- Damping at 2150 MHz (100m & 20° C): 21,4 dB
- Damping at 2150 MHz (100 ft. & 20 °C / 68 °F): 6.5227 dB
- Damping at 3000 MHz (100m & 20° C): 25,8 dB
- Damping at 3000 MHz (100 ft. & 20 °C / 68 °F): 7.8638 dB
- Impedance: 50 Ω
- Conductor resistance per 1 km: 4 Ω
- Conductor resistance per 1000 ft.: 1.2192 Ω
- Shield. resistance per 1 km: 7,4 Ω
- Shield. resistance per 1000 ft.: 2.2555 Ω
- Old article number: 999-0001-564
- BPVo-Euroclass: Fca