Downloads
Cable abuse without punishment...
This combination cable consists of three CAT cables interconnected with three DMX cables and is suitable for fixed installations as well as for mobile use.
Advantages:
- LAN signal transmission
- LAN cable also usable as an additional control line
Application:
- Control of DMX lighting consoles
- Mobile applications
- Analogue + digital audio multipair with LAN
- Permanent Installation
| Article number: | 500-0161-3 |
|---|---|
| Name: | SC-Monocat 303 |
| EAN: | 4049371539067 |
| Properties: | Analog, OFC oxygen free copper |
| Application area: | Installation, Mobile outdoor / indoor, Stage / live, Studio / Broadcast |
| Application: | hybrid cable |
| Colour: | black |
| Signal transmission: | symmetrical |
| Construction: | 3x(4x(2LI2Yx0,14mm²))(ST)CY+3x(2LI2Y0,25mm²)DY]Y |
| Construction (AES/EBU, DMX): | 3x(2LI2Y0,25mm²)DY |
| Construction (network): | 3x(4x(2LI2Yx0,14mm²))(ST)CY |
| Jacket material: | PVC |
| Jacket Ø [mm]: | 18.00 |
| Jacket Ø ["]: | 0.7087 |
| Jacket Ø (AES/EBU, DMX) [mm]: | 3,40 |
| Jacket Ø (AES/EBU, DMX) ["]: | 0.1339 |
| Jacket Ø (network) [mm]: | 6,40 |
| Jacket Ø (network) ["]: | 0.252 |
| Number of Channels (AES/EBU, DMX): | 3 |
| Number of Channels (network): | 3 |
| Inner conductor (AES/EBU, DMX): | 2 |
| Inner conductor (network): | 8 |
| Inner conductor (network) [sqin]: | 0.0002 |
| Inner conductor (AES/EBU, DMX) [mm²]: | 0.25 |
| Inner conductor (AES/EBU, DMX) [sqin]: | 0.0004 |
| Inner conductor (network) [mm²]: | 0,14 |
| AWG (AES/EBU, DMX): | 23 |
| Shielding (AES/EBU, DMX): | Copper spiral, tin-plated |
| Shielding (network): | AL / PT-foil + Copper braiding tin-plated |
| Shielding factor [%]: | 100 |
| Conductor insulation material: | Foam / Skin-PE |
| Conductor insulation Ø (AES/EBU, DMX) [mm]: | 1,30 |
| Conductor insulation Ø (AES/EBU, DMX) ["]: | 0.0512 |
| Conductor insulation Ø (network) [mm]: | 1,05 |
| Conductor insulation Ø (network) ["]: | 0.0413 |
| Weight per 1 m [g]: | 390 |
| Weight at 1000 ft. [lbs]: | 262.4372 |
| Style variant: | round |
| Packing: | bulk stock |
| CAT-Type: | CAT.7 |
| Max. section length [m]: | 100 |
| Max. section length [ft]: | 328.084 |
| Temperature min. [°C]: | -20 |
| Temperature max. [°C]: | 75 |
| Width [mm]: | 18 |
| Width ["]: | 0.7087 |
| Height [mm]: | 18 |
| Height ["]: | 0.7087 |
| Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF]: | 47 |
| Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF]: | 14.3256 |
| Capacity wire/wire at 1m (network) [pF]: | 44 |
| Capacity wire/wire at 1 ft. (network) [pF]: | 13.4112 |
| Surge impedance (AES/EBU, DMX) [Ω]: | 110 |
| Impedance (network) [Ω]: | 100 |
| Insulation resist. per 1 km (AES/EBU, DMX) [GΩ]: | 5 |
| Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ]: | 1.524 |
| Insulation resist. per 1 km (network) [GΩ]: | 5 |
| Insulation resist. per 1000 feet (network) [GΩ]: | 1.524 |
| Conductor resistance per 1 km (AES/EBU, DMX) [Ω]: | 87 |
| Conductor resistance per 1000 ft. (AES/EBU, DMX) [Ω]: | 26.5176 |
| Conductor resistance per 1 km (network) [Ω]: | 143 |
| Conductor resistance per 1000 ft. (network) [Ω]: | 43.5864 |
| BPVo-Euroclass: | Fca |
| Article number: | 500-0161-3 |
|---|---|
| Name: | SC-Monocat 303 |
| EAN: | 4049371539067 |
| Properties: | Analog, OFC oxygen free copper |
| Application area: | Installation, Mobile outdoor / indoor, Stage / live, Studio / Broadcast |
| Application: | hybrid cable |
| Colour: | black |
| Signal transmission: | symmetrical |
| Construction: | 3x(4x(2LI2Yx0,14mm²))(ST)CY+3x(2LI2Y0,25mm²)DY]Y |
| Construction (AES/EBU, DMX): | 3x(2LI2Y0,25mm²)DY |
| Construction (network): | 3x(4x(2LI2Yx0,14mm²))(ST)CY |
| Jacket material: | PVC |
| Jacket Ø [mm]: | 18.00 |
| Jacket Ø ["]: | 0.7087 |
| Jacket Ø (AES/EBU, DMX) [mm]: | 3,40 |
| Jacket Ø (AES/EBU, DMX) ["]: | 0.1339 |
| Jacket Ø (network) [mm]: | 6,40 |
| Jacket Ø (network) ["]: | 0.252 |
| Number of Channels (AES/EBU, DMX): | 3 |
| Number of Channels (network): | 3 |
| Inner conductor (AES/EBU, DMX): | 2 |
| Inner conductor (network): | 8 |
| Inner conductor (network) [sqin]: | 0.0002 |
| Inner conductor (AES/EBU, DMX) [mm²]: | 0.25 |
| Inner conductor (AES/EBU, DMX) [sqin]: | 0.0004 |
| Inner conductor (network) [mm²]: | 0,14 |
| AWG (AES/EBU, DMX): | 23 |
| Shielding (AES/EBU, DMX): | Copper spiral, tin-plated |
| Shielding (network): | AL / PT-foil + Copper braiding tin-plated |
| Shielding factor [%]: | 100 |
| Conductor insulation material: | Foam / Skin-PE |
| Conductor insulation Ø (AES/EBU, DMX) [mm]: | 1,30 |
| Conductor insulation Ø (AES/EBU, DMX) ["]: | 0.0512 |
| Conductor insulation Ø (network) [mm]: | 1,05 |
| Conductor insulation Ø (network) ["]: | 0.0413 |
| Weight per 1 m [g]: | 390 |
| Weight at 1000 ft. [lbs]: | 262.4372 |
| Style variant: | round |
| Packing: | bulk stock |
| CAT-Type: | CAT.7 |
| Max. section length [m]: | 100 |
| Max. section length [ft]: | 328.084 |
| Temperature min. [°C]: | -20 |
| Temperature max. [°C]: | 75 |
| Width [mm]: | 18 |
| Width ["]: | 0.7087 |
| Height [mm]: | 18 |
| Height ["]: | 0.7087 |
| Capac. cond./cond. per 1 m (AES/EBU, DMX) [pF]: | 47 |
| Capacity wire/wire at 1 ft. (AES/EBU, DMX) [pF]: | 14.3256 |
| Capacity wire/wire at 1m (network) [pF]: | 44 |
| Capacity wire/wire at 1 ft. (network) [pF]: | 13.4112 |
| Surge impedance (AES/EBU, DMX) [Ω]: | 110 |
| Impedance (network) [Ω]: | 100 |
| Insulation resist. per 1 km (AES/EBU, DMX) [GΩ]: | 5 |
| Insulation resist. per 1000 feet (AES/EBU, DMX) [GΩ]: | 1.524 |
| Insulation resist. per 1 km (network) [GΩ]: | 5 |
| Insulation resist. per 1000 feet (network) [GΩ]: | 1.524 |
| Conductor resistance per 1 km (AES/EBU, DMX) [Ω]: | 87 |
| Conductor resistance per 1000 ft. (AES/EBU, DMX) [Ω]: | 26.5176 |
| Conductor resistance per 1 km (network) [Ω]: | 143 |
| Conductor resistance per 1000 ft. (network) [Ω]: | 43.5864 |
| BPVo-Euroclass: | Fca |
SC-Monocat 303
hybrid cable
Advantages:
- LAN signal transmission
- LAN cable also usable as an additional control line
Application:
- Control of DMX lighting consoles
- Mobile applications
- Analogue + digital audio multipair with LAN
- Permanent Installation
Technical Data:
- Article number: 500-0161-3
- Name: SC-Monocat 303
- EAN: 4049371539067
- Properties: Analog
- Properties: OFC oxygen free copper
- Application area: Stage / live
- Application area: Mobile outdoor / indoor
- Application area: Studio / Broadcast
- Application area: Installation
- Application: hybrid cable
- Colour: black
- Signal transmission: symmetrical
- Construction: 3x(4x(2LI2Yx0,14mm²))(ST)CY+3x(2LI2Y0,25mm²)DY]Y
- Construction (AES/EBU, DMX): 3x(2LI2Y0,25mm²)DY
- Construction (network): 3x(4x(2LI2Yx0,14mm²))(ST)CY
- Jacket material: PVC
- Jacket Ø: 18,00 mm
- Jacket Ø: 0.7087 "
- Jacket Ø (AES/EBU, DMX): 3,40 mm
- Jacket Ø (AES/EBU, DMX): 0.1339 "
- Jacket Ø (network): 6,40 mm
- Jacket Ø (network): 0.252 "
- Number of Channels (AES/EBU, DMX): 3
- Number of Channels (network): 3
- Inner conductor (AES/EBU, DMX): 2
- Inner conductor (network): 8
- Inner conductor (network): 0.0002 sqin
- Inner conductor (AES/EBU, DMX): 0,25 mm²
- Inner conductor (AES/EBU, DMX): 0.0004 sqin
- Inner conductor (network): 0,14 mm²
- AWG (AES/EBU, DMX): 23
- Shielding (AES/EBU, DMX): Copper spiral, tin-plated
- Shielding (network): AL / PT-foil + Copper braiding tin-plated
- Shielding factor: 100 %
- Conductor insulation material: Foam / Skin-PE
- Conductor insulation Ø (AES/EBU, DMX): 1,30 mm
- Conductor insulation Ø (AES/EBU, DMX): 0.0512 "
- Conductor insulation Ø (network): 1,05 mm
- Conductor insulation Ø (network): 0.0413 "
- Weight per 1 m: 390 g
- Weight at 1000 ft.: 262.4372 lbs
- UV-resistant: yes
- Style variant: round
- Packing: bulk stock
- CAT-Type: CAT.7
- Max. section length: 100 m
- Max. section length: 328.084 ft
- Temperature min.: -20 °C
- Temperature max.: 75 °C
- Width: 18 mm
- Width: 0.7087 "
- Height: 18 mm
- Height: 0.7087 "
- Capac. cond./cond. per 1 m (AES/EBU, DMX): 47 pF
- Capacity wire/wire at 1 ft. (AES/EBU, DMX): 14.3256 pF
- Capacity wire/wire at 1m (network): 44 pF
- Capacity wire/wire at 1 ft. (network): 13.4112 pF
- Surge impedance (AES/EBU, DMX): 110 Ω
- Impedance (network): 100 Ω
- Insulation resist. per 1 km (AES/EBU, DMX): 5 GΩ
- Insulation resist. per 1000 feet (AES/EBU, DMX): 1.524 GΩ
- Insulation resist. per 1 km (network): 5 GΩ
- Insulation resist. per 1000 feet (network): 1.524 GΩ
- Conductor resistance per 1 km (AES/EBU, DMX): 87 Ω
- Conductor resistance per 1000 ft. (AES/EBU, DMX): 26.5176 Ω
- Conductor resistance per 1 km (network): 143 Ω
- Conductor resistance per 1000 ft. (network): 43.5864 Ω
- BPVo-Euroclass: Fca