Power Lead (N)YM-(ST)-J; 3 x 4.00 mm²; PVC, flame-retardant, Ø 11,80 mm; grey

You can rely on the NYM’s shielding...

For it protects not only against rain, but with this cable also from electromagnetic interference fields. Which is important in hospitals, server and computer areas and in every demanding studio as well as any radiation-sensitive living zones. The shielded {NAME cable with protective conductor is suitable for all indoor and outdoor installations (on, in and under plaster) insofar as these are not exposed to direct sunlight. The wires are color-coded pursuant to VDE 0293 and stranded in layers, with a tin-plated 1.5 mm² (0.002 sq in.) drain wire. The cables comply with the EC low voltage directive EWG93/68/ or EWG73/23.

Advantages:

  • EMC shielding against electromagnetic interfering signals
  • Complies with the VDE 0250, VDE 0482-332-1-2 / IEC 60332-1 standards and other requirements
  • mobile application up to +5°C

Application:

  • For all installations – especially in sensitive locations like e.g. hospitals, server rooms, studios
  • For surface and flush mounting as well as wet rooms
Article number: 720-0056-03040
Name: (N)YM-(ST)-J
EAN: 4049371051828
Properties: Analog, OFC oxygen free copper
Application area: ELA 100 V, Installation
Application: Power Lead
Colour: grey
Construction: (N)YM-(ST)-J
Jacket material: PVC, flame-retardant
Jacket material (power): PVC, flame retardant and self-extinguishing
Jacket Ø [mm]: 11,80
Jacket Ø ["]: 0.4646
Number of Channels (power): 1
Inner conductor (power): 3
Inner conductor (power) [mm²]: 4,00
Inner conductor (power) [sqin]: 0.0062
Inner conductor Ø (power) [mm]: 2,26
Inner conductor Ø (power) ["]: 0.089
AWG (power): 11
Shielding: AL / PT-foil + Tinned drain wire
Copper strands (power): 1
Copper strand Ø (power) [mm]: 1,78
Copper strand Ø (power) ["]: 0.0701
Conductor insulation material: PVC
Weight per 1 m [g]: 300
Weight at 1000 ft. [lbs]: 201.8748
Style variant: round
Packing: bulk stock
Temperature min. [°C]: -40
Temperature max. [°C]: 70
Width [mm]: 11,8
Width ["]: 0.4646
Height [mm]: 11,8
Height ["]: 0.4646
Insulation resist. per 1 km [GΩ]: 0,02
Insulation resist. per 1000 feet [GΩ]: 0.0061
Insulation resist. per 1km (power) [GΩ]: 0,02
Insulation resist. per 1000 feet (power) [GΩ]: 0.0061
Test voltage [V]: 2000
Nominal voltage (power) [V]: 500
Operating voltage (power) [V]: 350
Old article number: 720-0051-03040
BPVo-Euroclass: Fca
Article number: 720-0056-03040
Name: (N)YM-(ST)-J
EAN: 4049371051828
Properties: Analog, OFC oxygen free copper
Application area: ELA 100 V, Installation
Application: Power Lead
Colour: grey
Construction: (N)YM-(ST)-J
Jacket material: PVC, flame-retardant
Jacket material (power): PVC, flame retardant and self-extinguishing
Jacket Ø [mm]: 11,80
Jacket Ø ["]: 0.4646
Number of Channels (power): 1
Inner conductor (power): 3
Inner conductor (power) [mm²]: 4,00
Inner conductor (power) [sqin]: 0.0062
Inner conductor Ø (power) [mm]: 2,26
Inner conductor Ø (power) ["]: 0.089
AWG (power): 11
Shielding: AL / PT-foil + Tinned drain wire
Copper strands (power): 1
Copper strand Ø (power) [mm]: 1,78
Copper strand Ø (power) ["]: 0.0701
Conductor insulation material: PVC
Weight per 1 m [g]: 300
Weight at 1000 ft. [lbs]: 201.8748
Style variant: round
Packing: bulk stock
Temperature min. [°C]: -40
Temperature max. [°C]: 70
Width [mm]: 11,8
Width ["]: 0.4646
Height [mm]: 11,8
Height ["]: 0.4646
Insulation resist. per 1 km [GΩ]: 0,02
Insulation resist. per 1000 feet [GΩ]: 0.0061
Insulation resist. per 1km (power) [GΩ]: 0,02
Insulation resist. per 1000 feet (power) [GΩ]: 0.0061
Test voltage [V]: 2000
Nominal voltage (power) [V]: 500
Operating voltage (power) [V]: 350
Old article number: 720-0051-03040
BPVo-Euroclass: Fca

(N)YM-(ST)-J

Power Lead

Advantages:

- EMC shielding against electromagnetic interfering signals

- Complies with the VDE 0250, VDE 0482-332-1-2 / IEC 60332-1 standards and other requirements

- mobile application up to +5°C

Application:

- For all installations – especially in sensitive locations like e.g. hospitals, server rooms, studios

- For surface and flush mounting as well as wet rooms

Technical Data:

- Article number: 720-0056-03040

- Name: (N)YM-(ST)-J

- EAN: 4049371051828

- Properties: OFC oxygen free copper

- Properties: Analog

- Application area: Installation

- Application area: ELA 100 V

- Application: Power Lead

- Colour: grey

- Construction: (N)YM-(ST)-J

- Jacket material: PVC, flame-retardant

- Jacket material (power): PVC, flame retardant and self-extinguishing

- Jacket Ø: 11,80 mm

- Jacket Ø: 0.4646 "

- Number of Channels (power): 1

- Inner conductor (power): 3

- Inner conductor (power): 4,00 mm²

- Inner conductor (power): 0.0062 sqin

- Inner conductor Ø (power): 2,26 mm

- Inner conductor Ø (power): 0.089 "

- AWG (power): 11

- Shielding: AL / PT-foil + Tinned drain wire

- Copper strands (power): 1

- Copper strand Ø (power): 1,78 mm

- Copper strand Ø (power): 0.0701 "

- Conductor insulation material: PVC

- Weight per 1 m: 300 g

- Weight at 1000 ft.: 201.8748 lbs

- Style variant: round

- Packing: bulk stock

- Temperature min.: -40 °C

- Temperature max.: 70 °C

- Width: 11,8 mm

- Width: 0.4646 "

- Height: 11,8 mm

- Height: 0.4646 "

- Insulation resist. per 1 km: 0,02 GΩ

- Insulation resist. per 1000 feet: 0.0061 GΩ

- Insulation resist. per 1km (power): 0,02 GΩ

- Insulation resist. per 1000 feet (power): 0.0061 GΩ

- Test voltage: 2000 V

- Nominal voltage (power): 500 V

- Operating voltage (power): 350 V

- Old article number: 720-0051-03040

- BPVo-Euroclass: Fca

Loading...
Upload in progress, please be patient ...