580-0311-02
$24.93*
Downloads
Cable mono culture...
is what we did with the SC-Mercator QUAD 4 x CAT.7 and DUO 2 x CAT.7. Here we have packed no less than four or respectively two CAT.7 lines in a highly flexible and robust Strong PVC jacket. Each of the network lines is shielded against external interferences by an overall screen made of a braided copper mesh plus a foil screen per wire pair (PimF).
With the 10 Gbit-capable SC-Mercator QUAD 4 x CAT.7 / DUO 2 x CAT.7 up to 4 or 2 high-speed ethernet or compatible signals can be transmitted simultaneously.
Advantages:
- Four or respectively two high-speed lines in one robust jacket
- CAT.6a/10 GBit compatible
- Redundant transmission capability
- Highly flexible due to fine litz construction
Application:
- Linking of sound and light direction via separate networks
- For quick and efficient cabling, e.g. of LED video wall systems
- For all CAT.5e, CAT.6, CAT.6a and CAT.7 transmissions
Article number: | 580-0311-02 |
---|---|
Name: | SC-Mercator |
EAN: | 4049371446297 |
Properties: | Digital 110 Ω AES / EBU, OFC oxygen free copper |
Application area: | Installation, Stage / live, Studio / Broadcast |
Application: | Multipair Cat.7 |
Colour: | black |
Construction: | 2 x S/FTP 4x2x0,51mm |
Construction (network): | SFTP 4x2x0,51mm |
Jacket material: | PVC |
Jacket Ø [mm]: | 17.40 |
Jacket Ø ["]: | 0.7008 |
Number of Channels (network): | 2 |
Inner conductor (network): | 8 |
Inner conductor Ø (network) [mm]: | 0,51 |
Inner conductor Ø (network) ["]: | 0.0201 |
AWG (network): | 24 |
Shielding: | PimF, Copper braiding tin-plated |
Shielding factor [%]: | 100 |
Copper strands (network): | 1 |
Conductor insulation material: | Foam / Skin-PE |
Conductor insulation Ø [mm]: | 1,38 |
Conductor insulation Ø ["]: | 0.0543 |
Weight per 1 m [g]: | 260 |
UV-resistant: | yes |
Fire load per m [kWh]: | 0,15 |
Style variant: | round |
Packing: | 100 m spool, 500 m spool |
CAT-Type: | CAT.7 |
Max. section length [m]: | 140 |
Max. section length [ft]: | 459.3176 |
Velocity factor: | 0,77 |
Temperature min. [°C]: | -20 |
Temperature max. [°C]: | 60 |
Width [mm]: | 17,8 |
Width ["]: | 0.7008 |
Height [mm]: | 17,8 |
Height ["]: | 0.7008 |
Capacity wire/wire at 1m (network) [pF]: | 45 |
Capacity wire/wire at 1 ft. (network) [pF]: | 13.716 |
Impedance [Ω]: | 100 |
Insulation resist. per 1 km [GΩ]: | 5 |
Insulation resist. per 1000 feet [GΩ]: | 1.524 |
Insulation resist. per 1 km (network) [GΩ]: | 5 |
Insulation resist. per 1000 feet (network) [GΩ]: | 1.524 |
Loop resistance per km [Ω]: | 190 |
Loop resistance per 1000 ft. [Ω]: | 57.912 |
BPVo-Euroclass: | Fca |
Article number: | 580-0311-02 |
---|---|
Name: | SC-Mercator |
EAN: | 4049371446297 |
Properties: | Digital 110 Ω AES / EBU, OFC oxygen free copper |
Application area: | Installation, Stage / live, Studio / Broadcast |
Application: | Multipair Cat.7 |
Colour: | black |
Construction: | 2 x S/FTP 4x2x0,51mm |
Construction (network): | SFTP 4x2x0,51mm |
Jacket material: | PVC |
Jacket Ø [mm]: | 17.40 |
Jacket Ø ["]: | 0.7008 |
Number of Channels (network): | 2 |
Inner conductor (network): | 8 |
Inner conductor Ø (network) [mm]: | 0,51 |
Inner conductor Ø (network) ["]: | 0.0201 |
AWG (network): | 24 |
Shielding: | PimF, Copper braiding tin-plated |
Shielding factor [%]: | 100 |
Copper strands (network): | 1 |
Conductor insulation material: | Foam / Skin-PE |
Conductor insulation Ø [mm]: | 1,38 |
Conductor insulation Ø ["]: | 0.0543 |
Weight per 1 m [g]: | 260 |
UV-resistant: | yes |
Fire load per m [kWh]: | 0,15 |
Style variant: | round |
Packing: | 100 m spool, 500 m spool |
CAT-Type: | CAT.7 |
Max. section length [m]: | 140 |
Max. section length [ft]: | 459.3176 |
Velocity factor: | 0,77 |
Temperature min. [°C]: | -20 |
Temperature max. [°C]: | 60 |
Width [mm]: | 17,8 |
Width ["]: | 0.7008 |
Height [mm]: | 17,8 |
Height ["]: | 0.7008 |
Capacity wire/wire at 1m (network) [pF]: | 45 |
Capacity wire/wire at 1 ft. (network) [pF]: | 13.716 |
Impedance [Ω]: | 100 |
Insulation resist. per 1 km [GΩ]: | 5 |
Insulation resist. per 1000 feet [GΩ]: | 1.524 |
Insulation resist. per 1 km (network) [GΩ]: | 5 |
Insulation resist. per 1000 feet (network) [GΩ]: | 1.524 |
Loop resistance per km [Ω]: | 190 |
Loop resistance per 1000 ft. [Ω]: | 57.912 |
BPVo-Euroclass: | Fca |
SC-Mercator
Multipair Cat.7
Advantages:
- Four or respectively two high-speed lines in one robust jacket
- CAT.6a/10 GBit compatible
- Redundant transmission capability
- Highly flexible due to fine litz construction
Application:
- Linking of sound and light direction via separate networks
- For quick and efficient cabling, e.g. of LED video wall systems
- For all CAT.5e, CAT.6, CAT.6a and CAT.7 transmissions
Technical Data:
- Article number: 580-0311-02
- Name: SC-Mercator
- EAN: 4049371446297
- Properties: OFC oxygen free copper
- Properties: Digital 110 Ω AES / EBU
- Application area: Installation
- Application area: Stage / live
- Application area: Studio / Broadcast
- Application: Multipair Cat.7
- Colour: black
- Construction: 2 x S/FTP 4x2x0,51mm
- Construction (network): SFTP 4x2x0,51mm
- Jacket material: PVC
- Jacket Ø: 17.40 mm
- Jacket Ø: 0.7008 "
- Number of Channels (network): 2
- Inner conductor (network): 8
- Inner conductor Ø (network): 0,51 mm
- Inner conductor Ø (network): 0.0201 "
- AWG (network): 24
- Shielding: PimF, Copper braiding tin-plated
- Shielding factor: 100 %
- Copper strands (network): 1
- Conductor insulation material: Foam / Skin-PE
- Conductor insulation Ø: 1,38 mm
- Conductor insulation Ø: 0.0543 "
- Weight per 1 m: 260 g
- UV-resistant: yes
- Fire load per m: 0,15 kWh
- Style variant: round
- Packing: 100 m spool
- Packing: 500 m spool
- CAT-Type: CAT.7
- Max. section length: 140 m
- Max. section length: 459.3176 ft
- Velocity factor: 0,77
- Temperature min.: -20 °C
- Temperature max.: 60 °C
- Width: 17,8 mm
- Width: 0.7008 "
- Height: 17,8 mm
- Height: 0.7008 "
- Capacity wire/wire at 1m (network): 45 pF
- Capacity wire/wire at 1 ft. (network): 13.716 pF
- Impedance: 100 Ω
- Insulation resist. per 1 km: 5 GΩ
- Insulation resist. per 1000 feet: 1.524 GΩ
- Insulation resist. per 1 km (network): 5 GΩ
- Insulation resist. per 1000 feet (network): 1.524 GΩ
- Loop resistance per km: 190 Ω
- Loop resistance per 1000 ft.: 57.912 Ω
- BPVo-Euroclass: Fca